Model 6010 is specifically designed to meet the new OSHA and European safety standards which require that a single component failure will cause the control to shut down safely.
Model 6010 requires a machine operator to have both hands on start switches in order to begin a machine cycle. This minimizes the possibility of the operator having a hand in the work area when the machine starts. If one or both start switches are "tied-down", the output will not energize.
Positive Guided Output - The output consists of two relay contacts that are controlled by separate relays. Each relay is checked for proper status prior to beginning a machine cycle.
International Safety Compliance - The 6010 is designed to meet the European standards for two-hand control devices (EN 574) and the United States OSHA classification of "control reliable" as defined in section 1910.217 (13).
CE Marking - Nolatron uses the CE mark to designate that the 6010 is in compliance with the European standard for two-hand control devices (EN 574), and that it has been tested to emissions and immunity standards EN 50081-1 and EN 50082-1 and the Electromechanical Control Circuit Devices standard EN 60947-5-1. The use of CE marked component does not imply CE compliance of the finished product. The end user is responsible for determining that his machine is CE compliant. Additional testing may be required.

Installation
Be sure that electrical power is turned off before attempting to make wiring connections to the control. Make electrical connections according to the wiring diagram above. Use 18 gauge stranded copper wire that can withstand 60/75 degrees C. Tighten the wiring terminals to 1.0Nm. To protect the output contacts, a fuse (6A slow blow or 8A fast blow) should be connected before the output contacts as shown in the wiring diagram.
The 6010 must operate with additional external components as described below. The selection and connection of these additional components must conform to the relevant safety standard EN 574.
Start switches: The Start switches must be of a dry contact Form-C type. The operating voltage of the control determines the voltage that will be applied to the Start switches. These start switches must be mounted at a distance that prohibits the operator from releasing the switch and reaching into the danger zone. Please refer to EN 999 "Hand Velocity" for more information.
Loop & Reset circuits: The Loop circuit is used to prepare the control to begin a machine cycle, and the Reset circuit can be used to end it. Both circuits require switches of the dry contact type and rated for the supply voltage.
Load circuit: When the load device is inductive, a load suppressor should be used (Nolatron part no: 30165). Operating an inductive load without adequate suppression will greatly reduce the life of the output contacts.
Operation
To prepare the control for a machine cycle: power is applied, both Start switches are open and the Loop circuit is closed. Indicators SW1/SW2 both light when these conditions are met.
To begin a machine cycle: the Reset circuit must be closed and both Start switches must be pressed simultaneously (within .5 sec.). When these conditions are met, indicators SW1/SW2 will go out, indicators K1/K2 will both light, and the output relays will energize.
To end the machine cycle: The output will open when either or both Start switches are released. The machine cycle can also be ended by momentarily opening the Reset circuit regardless of whether the start switches are still depressed. In some applications the Reset switch is used as a means to provide a "single stroke" of the machine.
Operation when a fault occurs: The control will not energize the output circuit due to an internal fault condition. Should a fault take place, the control should be replaced. For safety reasons, Nolatron does not recommend that anyone attempt to service the control for any reason.
Note: The Loop and Reset switches must be closed before a machine cycle can be started. These switches are optional and are not required for all applications. Do not remove the factory installed jumper wires unless you intend to install these optional switches.
WARNING: These anti-tiedown controls are not intended for use without adequate point of operation safety guards, which must be provided for the operator's protection. The user must see that these controls are properly installed, cared for and operated to meet all applicable local and national requirements. Failure to comply could result in serious bodily injury and/or properly damage.
Specifications
| European Standards | |
| Utilization | Category AC-15 |
| Intermittent Duty | Class 1200 (max. switching frequency of 1200 cycles/hour) |
| Radiation Standards | EMV/EMC/CEM EN50081-1, EN 50082-2 |
| Other Standards | EN 60947-5-1 |
| Safety Classification | EN574 category 4, type IIIc |
| Typical Applications | Eccentric (EN 692) and Hydraulic (EN693) power presses |
| Minimum Clearance | Mounting IP52, Housing IP40, Terminals IP20 |
| Rated Insulation (Ui) | 250VAC (rms) |
| Max impulse (Uimp) | 500 VAC (rms) |
| Rated operational current (Ie) | .8 Amp |
| Suitability for isolation | Not suitable |
| Physical | |
| Size | 75mm long, 55mm Wide, 110mm Deep |
| Weight | 400 grams |
| Mounting | DIN-Rail compatible or mounting holes (use two 3.5mm screws) |
| Wiring connection | Screw terminals, for 18 gauge stranded wire, Torque to 1.0 Nm |
| Drop Height | 1 meter max. |
| Housing Material | Polycarbonate, UL94 flame class V-2, NEMA 12 (IEC IP52) |
| Vibration Resistance | 10-55HZ @ .35mm |
| Environmental | |
| Temperature Range | -10 to +55 C (operating) -25 to +85 C (storage) |
| Classification | Microenvironmental pollution degree 3 |
| Climate condition | DIN 40040 Class F |
| Humidity | 50% max. @ 40 deg. C., Altitude not to exceed 2000m. |
| Start Switches | |
| Type required | Dry contact Form-C, w/min. rating of 115 VAC @ 1 amp. |
| Concurrent time | Both start switches must be pressed within 0.5 sec. |
| Recovery time | The start switches must be open for at least one second |
| Optional Switches | |
| Loop circuit | Dry contact Form A, w/min. rating of 115 VAC @ 1 amp. |
| Reset circuit |
Dry contact Form B, w/min. rating of 115
VAC @ 1 amp. (30 millisecond response time) |
| Operating Power (Ue) | 115 VAC ( + 15%), 50/60Hz. @ 250ma. |
| Power consumption | less than 5 watts |
| External protection of unit: | 1/2 Amp fuse |
| Output | |
| Type | 2 normally open safety contacts, positive guided |
| Switching Current (normal) | 8 Amps @ 250 VAC (maximum inrush current) |
| Switching Current (abnormal) | 10 Amps @ 250 VAC |
| Conditional short-circuit rating | 10 Amps @ 250 VAC |
| Switching Overvoltage | 500 VAC (rms) |
| Continuous Current (Ithe) | .8 Amps @ 100% duty cycle (enclosure > 8000 sq. cm.) |
| Max. Voltage | 250 VAC (rms) / 300 VDC |
| Response time | 40ms operate / 50ms release |
| Protection of Contact | External 6 Amp slow or 8 Amp fast acting fuse (VDE 0600 Pt. 200) |
| Life | 10 million mechanical operations (minimum) |