NOLATRON, INC.
ANTI-TIE DOWN CONTROL
WITH A NORMALLY CLOSED CONTACT

MODEL 3380-C

3380cpic.jpg (87107 bytes)
Nolatron's Model 3380-C uses redundant positive guided contact output contacts which are cross-checked before every machine cycle. A single component failure will cause the control to shut down in a safe mode.

       

Features:

 

3380cwir.gif (20595 bytes)NORMALLY CLOSED CONTACT: When both start switches are pressed within .5 seconds, the pin 5 contacts close and the pin 4 normally closed contact opens. When one or both switches are released or the reset switch is opened, the pin 5 contacts open and the pin 4 contact closes. The Hold switch shown above can also be used in conjunction with the normally closed contact. Note: The normally closed contact on pin 4 is not monitored, and should not be used to drive a load that needs "control reliable" protection.

 

Nolatron, Inc.